Up to now, Doppler ultrasonic flow meters have required significant quantities of suspended particles or gas bubbles to reflect sound signals. Now, with the Model FD-7000 UltrasonicFlowmeter, this is no longer required. When the FD-7000 is used to measure the flow of liquids containing suspended solids or bubbles, the transducers are mounted on a straight run of pipe in the same manner as other ultrasonic meters.
In applications where insufficient “reflectors” exist (a condition indicated by a low reading on the FD-7000’s Flow Analyzer bar graph), the transducers are relocated to a point in the piping where non-symmetrical hydraulic turbulence will be present – ideally just downstream of a 90-degree elbow. The FD-7000’s unique digital filtering system and signal recognition circuitry transforms the reflections from this non-symmetrical, and not necessarily linear, turbulence into a useable and linear data format.
A backlit, 2 line by 20 character, alphanumeric LCD offers simultaneous flowrate and totalizer displays. The FD-7000 is designed for ease of use in the field. Only a few simple keypad entries are required to configure the flowmeter for any given pipe and flow measurement application. The encapsulated, submersible design of the transducer sensor head allows it to be easily mounted to the pipe surface with the coupling compound and elastic bands that are supplied with the unit.
A 20 ft. (6 meter) retractable cable for connection to the transmitter/indicator unit is supplied as as integral part of the sensor. The FD-7000 sensor is utilized on pipes that range in internal diameter from 25 to 3048 mm (1 to 120"). Flowrates can be measured in smaller pipes from 6 to 25 mm ( 1 /4 to 1") in diameter with use of the small pipe sensor, model FD-7000-S1. These units are not to be used for distilled water or ultra clean water applications.
Ultrasonic Flowmeter FD-7000 is made in USA and advertised at www.omega.com.
SPECIFICATIONS
System Accuracy:
±2% of F.S.
Velocity Range:
0.15 to 6.2 meters/second (0.5 to 20 feet/second)
Measuring Units:
FPS, GPM, MGD
Linearity:
±0.2% of F.S.
Repeatability:
0.4% of F.S.
Flow Rate Display:
6-digit LCD
Totalizer Display:
6-digit LCD (resettable)
Outputs:
4 to 20 mA into 600 Ohms max., isolated
Power Requirements:
115 Vac ±10%, 50/60 Hz, 20 VA max. (standard); 230 Vac 50/60 Hz (optional). Internal gel cell battery provides 8 hrs. of continuous operation
Liquid Requirements:
Full-pipe, low-viscosity (water-like) liquid
Transmitter/Indicator Operating
Temperature:
-30 to 70°C (-22 to 158°F)
Sensor Operating Temperature:
-40 to 121°C (-40 to 250°F)
Dimensions:
432 L x 279 W x 203 mm H
(17 x 11 x 8")
Weight:
10 kg (22 lb)
Enclosure:
NEMA-4X (IP65)